• Do not use hazardous chemicals to clean or come into contact with the unit.
Do not use the unit in the presence of inflammable substances or vapour
such as alcohol, insecticides, petrol,etc.
• Always transport your air conditioner in a vertical position and stand on a
stable, level surface during use.
• Always contact a qualified person to carry out repairs. If the damaged power
supply cord must be replaced with a new power supply cord obtained from
the product manufacturer and not repaired.
• Hold the plug by the head of the power plug when taking it out.
• Turn off the product when not in use.
CAUTION
Safety
Precautions
WARNING for Using R32 Refrigerant
Electronic Work
WARNING:
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition
sources (for example:open flames, an operating gas appliance or an operating
electric heater).
Do not pierce or burn.
Be aware that the refrigerants may not contain an odour.
Appliance should be installed, operated and stored in a room with a floor area
according to the amount of refrigerant to be charged. For specific information on
the type of gas and the amount, please refer to the relevant label on the unit itself.
When there are dierences between the lable and the manual on the Min. room
area description, the description on label shall prevail.
Appliance shall be installed, operated and stored in a room with a floor area larger
than 4 m
2
.
Appliance shall not be installed in an unvertilated space, if that space is smaller than
4 m
2
.
No any open fire or device like switch which may generate spark/arcing shall be
around appliance to avoid causing ignition of the flammable refrigerant used.
Please follow the instructions carefully when storing or maintaining the appliance
to prevent mechanical damage from occurring.
DISPLAY
BEFORE PERFORMING ANY ELECTRICAL OR WIRING WORK, TURN OFF THE
MAIN POWER TO THE SYSTEM.
MAIN
CONTROL
POWER
NOTE: The cographs are for
explanation purpose only. Your
machine may be slightly dierent.
The actual shape shall prevail.
SUPPLY
CORD