Aqua Tempo Super II Series DC Inverter Air-cooled chiller unit (50Hz) MCAC-ATSM-201704
19
10.Capacity Tables
10.1 Cooling
MC-SU30-RN1L
Ambient
temp.
Chilledwateroutlettemperature(℃)
3.00 7.00 10.00 15.00
20.00
Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power
℃
kW kW kW kW kW kW kW kW kW kW
-15 22.98 6.08 26.20 5.93 28.64 6.54 29.65 6.80
32.12 7.11
-5 21.99 6.18 24.79 6.75 27.01 6.80 30.16 7.32
31.90 7.28
5.00 21.75 6.14 24.88 6.91 26.87 6.89 30.01 7.39
31.13 7.31
10.00 20.78 5.92 24.57 6.98 26.54 6.89 29.87 7.45
30.14 7.32
17.00 40.18 11.41 42.86 11.91 46.28 12.61 51.28 13.75
56.25 13.75
25.00 35.87 10.68 38.49 11.39 40.89 11.78 45.29 12.69
50.19 12.90
30.00 31.98 10.09 33.58 10.36 35.24 10.55 39.49 11.55
46.551 13.30
35.00 30.54 12.31 31.11 11.96 32.18 10.12 34.17 10.95
40.761 12.17
40.00 16.98 8.01 17.26 7.74 19.23 8.32 20.89 8.42
35.611 11.87
45.00 10.52 6.19 12.65 6.63 17.29 8.56 18.98 8.66
20.376 8.75
Note:
This table is measured in rated water flow.
MC-SU60-RN1L
Ambient
temp.
Chilledwateroutlettemperature(℃)
3.00 7.00 10.00 15.00
20.00
Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power
℃
kW kW kW kW kW kW kW kW kW kW
-15 44.77 12.30 51.01 11.99 55.76 13.23 57.71 13.76
62.51 14.37
-5 42.84 12.50 48.27 13.66 52.60 13.76 58.69 14.80
62.08 14.73
5.00 42.39 12.44 48.46 13.98 52.32 13.94 58.41 14.95
60.58 14.78
10.00 40.50 11.98 47.86 14.12 51.68 13.94 58.14 15.06
58.66 14.79
17.00 78.14 23.06 83.34 24.04 89.97 25.47 99.67 27.76
109.32 27.77
25.00 69.78 21.57 74.86 23.00 79.52 23.80 88.05 25.62
97.56 26.05
30.00 62.23 20.38 65.34 20.94 68.56 21.31 76.79 23.32
90.50 26.85
35.00 59.44 24.86 60.54 24.16 62.62 20.45 66.47 22.12
79.27 24.57
40.00 33.13 16.20 33.67 15.65 37.49 16.83 40.72 17.03
69.28 23.97
45.00 20.60 12.55 24.74 13.42 33.73 17.31 37.01 17.50
39.72 17.63
Note:
This table is measured in rated water flow.