MCAC-ATSM-201704 Aqua Tempo Super II Series DC Inverter Air-cooled chiller unit (50Hz)
9.Electric Characteristics
Model
Outdoor Unit Power Supply Compressor OFM
Hz Voltage Min. Max. TOCA MFA LRA RLA kW FLA
MC-SU30-RN1L 50 380-415 342 456 50 36 68.9 68.9 0.45 3.1
MC-SU60-RN1L 50 380-415 342 456 100 70 68.9 68.9 1.2 3.7
Remark:
TOCA: Total Over-current Amps. (A)
MFA: Max. Fuse Amps. (A)
LRA: Locked Rotor Amps. (A)
RLA: Rated Locked Amps. (A)
OFM: Outdoor Fan Motor.
FLA: Full Load Amps. (A)
kW: Rated Motor Input (kW)