Electrical Control Function
Electrical Control System 179
1.3 Operation Modes and Functions
1.3.1 Fan mode
(
1) Outdoor fan and compressor stop.
(2) Temperature setting function is disabled, and no setting temperature is displayed.
(3) Indoor fan can be set to high/(med)/low/auto.
(4) The louver operates same as in cooling mode.
(5) Auto fan:
For Compact Cassette 12k &GA floor standing:
For GA floor standing:
For Ceiling and floor 12k&Console 12k:
27.5
27
High
Low
25
Medium
25.5
For A5 duct 12k :
T1
High
27C
25C
Low
T1
High
27C
26C
Low
T1
27 High
26
Medium
24
Low

Table of Contents