Troubleshooting
198 Electrical Control System
6 IPM module protection X X O E5
7
Open or short circuit of T3 or T4 temperature
sensor
O X X E6
8 Outdoor unit voltage protection O X O P0
9 Compressor temperature protection X O X P1
10 Outdoor unit over-current protection X P2
O(light) X(off) (flash at 5Hz)
For console type(12K)
NO. Malfunction Running lamp Timer lamp Defrosting lamp
1
Communication malfunction between indoor and outdoor
units.
X X
2 Open or short circuit of T1 temperature sensor X X
3 Open or short circuit of T2 temperature sensor X X
4 Indoor EEPROM malfunction X
5 IPM module protection X
6 Open or short circuit of T3 or T4 temperature sensor
7 Outdoor unit voltage protection O
8 Outdoor unit over-current protection O O
9 Top temperature protection of compressor O X
10 Inverter compressor drive protection
X
11 Indoor fan Speed has been out of control.
O
12 Outdoor fan malfunction
X
O
O(light) X(off) (flash at 5Hz) (flash at 0.5Hz)
For console type(18K)
NO. Malfunction Running lamp Timer lamp Defrosting lamp
1 Indoor EEPROM malfunction
2 Indoor fan Speed has been out of control. X
3 Open or short circuit of T1 or T2 temperature sensor X
4
Communication malfunction between indoor and outdoor
units.
X X
5 Outdoor unit malfunction X X
X(off) (flash at 5Hz) (flash at 0.5Hz)
For compact 4-way cassette(18K)&ceiling & floor(18-30K)
NO. Malfunction Running lamp Timer lamp Defrosting lamp Alarm lamp
1
Communication malfunction between indoor and
outdoor units.
X X X
2 Open or short circuit of T1 or T2 temperature sensor X X X
3 Full-water malfunction X X X
4 Outdoor unit malfunction X X X
X(off) (flash at 5Hz) (flash at 0.5Hz)