Table 2-5.3: MHC-V22W/D2RN8 heating capacity - peak values
1
Outdoor
air temp.
LWT (C)
30
35
40
45
50
55
60
C DB
HC
PI
COP
HC
PI
COP
HC
PI
COP
HC
PI
COP
HC
PI
COP
HC
PI
COP
HC
PI
COP
-25.0
9328
6216
1.50
8359
6583
1.27
-20.0
12899
6067
2.13
11566
6424
1.80
10234
6782
1.51
-15.0
19637
7474
2.63
19112
8206
2.33
17334
9221
1.88
15482
10266
1.51
13359
10279
1.30
-7.0
24093
8159
2.95
23733
9254
2.56
23791
9963
2.39
23836
10691
2.23
21846
10470
2.09
13558
10441
1.30
9946
8124
1.22
-2.0
28722
8702
3.30
27958
9343
2.99
27680
10163
2.72
27375
11005
2.49
23397
10626
2.20
18573
11196
1.66
14958
11305
1.32
2.0
29878
7993
3.74
29100
8743
3.33
28321
9492
2.98
27542
10242
2.69
27112
10959
2.47
24629
10778
2.29
22717
11224
2.02
7.0
25997
6215
4.18
24925
6468
3.85
23891
7096
3.37
22657
7511
3.02
22706
8542
2.66
22775
9089
2.51
22443
10552
2.13
15.0
28916
6484
4.46
28048
6789
4.13
27180
7095
3.83
26312
7401
3.56
25450
7657
3.32
24588
7913
3.11
23726
8169
2.90
20.0
28642
6171
4.64
27752
6407
4.33
26862
6644
4.04
25972
6881
3.77
24963
7064
3.53
23953
7248
3.30
22944
7431
3.09
25.0
28913
6010
4.81
27988
6192
4.52
27063
6373
4.25
26138
6555
3.99
24984
6679
3.74
23830
6803
3.50
22676
6928
3.27
30.0
30920
6224
4.97
29906
6364
4.70
28892
6505
4.44
27878
6645
4.20
26518
6722
3.95
25158
6798
3.70
23799
6875
3.46
35.0
12748
1735
7.35
12458
1923
6.48
12167
2110
5.77
11877
2298
5.17
11536
2619
4.41
11196
2940
3.81
Abbreviations:
LWT: Leaving water temperature (°C )
HC: Total heating capacity (W)
PI: Power input (W)
Notes:
1.Integrated heating capacity values take account of capacity drops caused by frost accumulation and during defrosting.
Table 2-5.4: MHC-V22W/D2RN8 heating capacity - integrated values
1
Outdoor
air temp.
LWT (C)
30
35
40
45
50
55
60
C DB
HC
PI
COP
HC
PI
COP
HC
PI
COP
HC
PI
COP
HC
PI
COP
HC
PI
COP
HC
PI
COP
-25.0
7995
5857
1.37
7374
6340
1.16
-20.0
11062
5716
1.94
10223
6188
1.65
9383
6660
1.41
-15.0
17158
7178
2.39
15913
7348
2.17
14246
8564
1.66
12511
9818
1.27
11206
10007
1.12
-7.0
22348
8404
2.66
21279
8704
2.44
20570
9223
2.23
19824
9754
2.03
17426
9425
1.85
12547
10034
1.25
9204
7904
1.16
-2.0
24215
8052
3.01
23364
8471
2.76
22915
9219
2.49
22435
9988
2.25
18925
9595
1.97
15713
10074
1.56
13392
10067
1.33
2.0
23355
6959
3.36
23244
7692
3.02
23132
8425
2.75
23021
9157
2.51
22908
9959
2.30
21042
9933
2.12
19629
10005
1.96
7.0
25997
6215
4.18
24925
6468
3.85
23891
7096
3.37
22657
7511
3.02
22706
8542
2.66
22775
9089
2.51
22443
10552
2.13
15.0
28916
6484
4.46
28048
6789
4.13
27180
7095
3.83
26312
7401
3.56
25450
7657
3.32
24588
7913
3.11
23726
8169
2.90
20.0
28642
6171
4.64
27752
6407
4.33
26862
6644
4.04
25972
6881
3.77
24963
7064
3.53
23953
7248
3.30
22944
7431
3.09
25.0
28913
6010
4.81
27988
6192
4.52
27063
6373
4.25
26138
6555
3.99
24984
6679
3.74
23830
6803
3.50
22676
6928
3.27
30.0
30920
6224
4.97
29906
6364
4.70
28892
6505
4.44
27878
6645
4.20
26518
6722
3.95
25158
6798
3.70
23799
6875
3.46
35.0
12748
1735
7.35
12458
1923
6.48
12167
2110
5.77
11877
2298
5.17
11536
2619
4.41
11196
2940
3.81
Abbreviations:
LWT: Leaving water temperature (°C )
HC: Total heating capacity (W)
PI: Power input (W)
Notes:
1.Integrated heating capacity values take account of capacity drops caused by frost accumulation and during defrosting.
Midea CAC Confidential

Other manuals for Midea MHC- V30W/D2RN8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea MHC- V30W/D2RN8 and is the answer not in the manual?

Midea MHC- V30W/D2RN8 Specifications

General IconGeneral
BrandMidea
ModelMHC- V30W/D2RN8
CategoryAir Conditioner
LanguageEnglish

Related product manuals