EXHAUSTING REQUIREMENTS
WARNING
The dryer shall not be exhausted into a chimney, a wall, a ceiling, an
attic, a crawl space, or a concealed space of a building.
The dryer must be exhausted to the outside to reduce the risk of fire
when installed in alcove or closet.
Exhausting the dryer to the outside will prevent large amounts of lint and
moisture from being blown into the room.
WARNING
NEVER USE A PLASTIC OR NON-METAL FLEXIBLE DUCT
If your existing ductwork is plastic, non-metal, or combustible, replace it
with metal before installation this appliance
Use only a metal exhaust duct that is non-flammable to ensure
containment of the exhaust air heat, and lint.
Refer to the “Ducting requirements” section on page 13 for the
maximum duct length and number of bends.
All dryers must be exhausted to the outside.
Do not assemble the duct with screws or other fastening means that
extend into the duct and catch lint.
The exhaust duct should be 4 inches (102mm) in diameter.
The total length of flexible metal duct shall not exceed 7.8 feet
(2.4 meters).
GAS REQUIREMENTS
Use only natural or LP (liquid propane) gases.
THE INSTALLATION MUST CONFORM WITH LOCAL CODES, OR IN THE
ABSENCE OF LOCAL CODES, WITH THE NATIONAL FUEL GAS CODE, ANSI
Z223.1/NFPA 54, LATEST REVISION (FOR THE UNITED STATES), OR THE
NATURAL GAS AND PROPANE INSTALLATION CODE, CSA B149.1, LATEST
REVISION (FOR CANADA).
Gas dryers are equipped with a burner vent for use with natural gas. If you
plan to use your dryer with LP (liquid propane) gas, it must be converted
for safe and proper performance by a qualified service technician.
A
 " (1.27 cm) gas supply line is recommended and must be reduced to
connect to the  " (1 cm) gas line on your dryer. The National Fuel Gas
Code requires that an accessible, approved manual gas shut-off valve be
installed within 6" (15,24 cm) of your dryer.
Gas dryers installed in residential garages must be raised 18" (46cm)
above the floor.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea MLE52S7AWW and is the answer not in the manual?

Midea MLE52S7AWW Specifications

General IconGeneral
BrandMidea
ModelMLE52S7AWW
CategoryDryer
LanguageEnglish

Related product manuals