8.4 Operation Modes and Functions 
8.4.1 Fan mode 
(1) Outdoor fan and compressor stop. 
(2) Temperature setting function is disabled, 
and no setting temperature is displayed. 
(3) Indoor fan can be set to 
high/med/low/auto. 
(4) The louver operates same as in cooling 
mode. 
(5) Auto fan: 
For MS11M-09HRFN1-MW0W, 
MS11M-12HRFN1-MV0W, 
MS11M-18HRFN1-MU0W models: 
a
b
c
d
6.0¡ãC(42.8¡ãF)
T1-24¡ãC(75.2¡ãF)
e
H
(H-L)*0.75+L
(H-L)*0.5+L
(H-L)*0.25+L
L
5.0¡ãC(41.0¡ãF)
4.0¡ãC(39.2¡ãF)
2.5¡ãC(36.5¡ãF)
1.0¡ãC(33.8¡ãF)
For MS11M-24HRDN1-MT0W model:   
27.5¡ãC(81.5¡ãF)
T1
27.0¡ãC(80.6¡ãF)
High
Low
25.0¡ãC(77.0¡ãF)
Medium
25.5¡ãC(77.9¡ãF)
 
8.4.2 Cooling Mode 
8.4.2.1 Compressor running rules 
The maximum operation frequency of 
compressor after starting submits to following 
rule. 
45¡ãC(113¡ãF)
40¡ãC(104¡ãF)
38¡ãC(100.4¡ãF)
31.5¡ãC(88.7¡ãF)
29.5¡ãC(85.1¡ãF)
22.0¡ãC(71.6¡ãF)
20.0¡ãC(68.0¡ãF)
Fmax=F4
Fmax=F7
Fmax=F8
Fmax=F6
Fmax=F3
T4
43¡ãC(109.4¡ãF)
Fmax: The maximum operation frequency of 
compressor. 
F1~F8: The detailed value of the compressor 
operation frequency. 
If users switch on AC by remote controller, the 
compressor will run at the Fmax frequency for 7 
minutes according to the outdoor ambient temp. 
During the 7 minutes, the frequency limitation is 
active. 7 minutes later, the compressor running 
frequency will be controlled as below: 
3.5¡ãC(38.3¡ãF)
-0.5¡ãC(31.1¡ãF)
T1-Ts
-1.0¡ãC(30.2¡ãF)
A
B
C
D
E
F
G
H
3.0¡ãC(37.4¡ãF)
2.5¡ãC(36.5¡ãF)
2.0¡ãC(35.6¡ãF)
1.5¡ãC(34.7¡ãF)
1.0¡ãC(33.8¡ãF)
0.5¡ãC(32.9¡ãF)
While the zones of A,B,C... are corresponding 
to different compressor running frequency. 
 
Note: