MCAC-UTSM-2008-11 Accessories
Indoor Units 51
11. Accessories
Installation Fittings
Name Shape Quantity
1. Expansible hook
4
3. Installation paper board
4
Tubing & Fittings
5. Connecting pipe group 1
6. Binding tape
6
7.Soundproof/insulation sheath
2
Drainpipe Fittings
8. Out-let pipe sheath
1
Protect Pipe Fittings
13. Wall conduit
1
Remote controller & Its
Frame
15. Remote controller
1
17. Mounting screw(ST2.9×10-C-H)
2
18. Alkaline dry batteries (AM4)
2
Others
19. Owner's manual
1
20. Installation manual
1
12. The Specification of Power
Type MCC-24HRN1 MCC-30HRN1 MCC-30HRN1-R
Power
Phase 1-phase 1-phase 3-phase
Frequency and
Voltage
220-240V, 50Hz 220-240V, 50Hz 380-415V, 50Hz
Circuit Breaker/ Fuse (A) 40/25 40/25 25/15
Indoor Unit Power Wiring (mm
) 3×4.0 3×4.0 5×2.5
Indoor/Outdoor Connecting
Wiring (mm
2
)
Ground Wiring 4.0 4.0 2.5
Outdoor Unit Power
Wiring
3×4.0 3×4.0 5×2.5
Strong Electric
Signal
3×2.5 3×2.5 3×1.0
Weak Electric Signal
1-core shield wire
1×0.5
1-core shield wire
1×0.5
Type MCC-36HRN1 MCC-36HRN1-R
Power
Phase 1-phase 3-phase 3-phase
Frequency and Voltage
220-240V, 50Hz 380-415V, 50Hz
Circuit Breaker/ Fuse (A) 40/25 25/15 25/15
Indoor Unit Power Wiring (mm
) 3×4.0 5×2.5 5×2.5
Indoor/Outdoor Connecting Wiring
(mm
2
)
4.0 4.0 2.5 2.5
Outdoor Unit Power
Wiring
3×4.0 5×2.5 5×2.5
Strong Electric Signal 3×2.5 3×1.0 3×1.0
Weak Electric Signal
1-core shield wire
1×0.5