A: The compressor keeps running for 40 minutes or more.
B: The temperature difference of evaporator temp and room temperature meets one of
the following:
Temp. of evaporator---room temp.
Fan speed is high
TH
DEFROST
Fan speed is mid
TM
DEFROST
Fan speed is low
TL
DEFROST
Breeze Meet only if it is Breeze
Calculate from the end of latest defrost, evaporator high temp. protection only closes
outdoor fan with the compressor still running. Add up to 90 minutes.
8.9.2 Defrosting time
If the temp. difference condition is satisfied for less than 40 minutes, this can be
regarded as severe frosting. The defrosting time is 10 minutes.
If the temp. difference condition is satisfied for more than 40 minutes, the defrosting
time is 6 minutes.
If the temp. difference condition is satisfied out of 40 minutes, generally the
defrosting time is 6 minutes, after three continuous 6-minute defrosting , the fourth
defrosting time is 10 minutes. The circulation is as following:
6-minute defrost 6-minute defrost6-minute defrost10-minute defrost
8.9.3 Ending condition of defrosting
If one of following conditions is satisfied, end the defrost and turn into heating:
A. The defrost time has reached to 6 or 10 minutes.
B. The compressor current has reached to I
DEFROST
or above, I
DEROST
differs in different
models.
8.9.4 Defrosting Actions:
Defrost 10or 6minutes
45S 25S
Compressor
4-way Valve 23S
40S
Outdoor Fan
Indoor Fan
10S
8.9.7 Turn into heating mode, turn off the heating mode in 7 minutes
8.10 Automatic operation mode
154