EasyManua.ls Logo

Midea MSH-07CRN1, MSH-07HRN1, MSH-09CRN1, MSH-09HRN1, MSH-12CRN1, MSH-12HRN1 - Page 323

Midea MSH-07CRN1, MSH-07HRN1, MSH-09CRN1, MSH-09HRN1, MSH-12CRN1, MSH-12HRN1
359 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
T> TE6 On On
Evaporator Temp. up
T< TE6 >5 Minutes Off Off
T> TE5 On On
Evaporator Temp.
down
T< TE5 >5 Minutes Off Off
8.10 Dehumidifying mode
8.7.6 The 4-way valve is off in dehumidifying mode
8.7.7 Compressor and Indoor Fan actions in dehumidifying mode
Indoor Fan Compressor and Outdoor Fan
LOW
BREEZE
ON 5minutes
OFF 5minutes
Repeat on and off cycle.
8.7.8 Low room temperature protection:
When room temperature decreases to below 10, compressor and outdoor fan will
stop(indoor fan is Breeze). Dehumidifying operation will be resumed when room
temperature restores to over 13.
8.7.9 At dehumidifying mode, the anti-freezing function of the indoor heat exchanger is the
same as that of cooling mode.
8.7.10 At dehumidifying mode, the action of fans of indoor is the same as that of air-only
mode.