24
7.4.10 Point check function 
Press the LED DISPLAY or LED or MUTE button of the remote controller three times, and then press 
the AIR DIRECTION or SWING button three times in ten seconds, the buzzer will keep ring for two 
seconds. The air conditioner will enter into the information enquiry status. You can press the LED 
DISPLAY or AIR DIRECTION button to check the next or front item’s information. 
When the AC enter the “information enquiry” status, it will display the code name in 2 seconds, the 
details are as follows. 
Enquiry information  Displaying code
Meaning 
T1  T1  T1 temp. 
T2  T2  T2 temp. 
T3  T3  T3 temp. 
T4  T4  T4 temp. 
T2B  Tb  T2B temp. 
TP  TP  TP temp. 
TH  TH  TH temp. 
Targeted Frequency  FT  Targeted Frequency 
Actual Frequency  Fr  Actual Frequency 
Indoor fan speed  IF  Indoor fan speed 
Outdoor fan speed  OF  Outdoor fan speed 
EXV opening angle  LA  EXV opening angle 
Compressor continuous running time  CT  Compressor continuous 
running time 
Causes of compressor stop.  ST  Causes of compressor 
stop. 
Reserve  A0   
Reserve    A1   
Reserve    0   
Reserve    1   
Reserve    2   
Reserve    3   
Reserve    4   
Reserve    5   
Reserve    6   
Reserve    L   
Reserve    A    
Reserve    U    
Reserve    T    
 
When the AC enter into the information enquiry status, it will display the code value in the next 25s, the 
details are as follows.