Commercial Air Conditioners
R410A
Service
Manual
V8 VRF Indoor Units
Question and Answer IconNeed help?

Do you have a question about the Midea V8 VRF Series and is the answer not in the manual?

Midea V8 VRF Series Specifications

General IconGeneral
SeriesV8 VRF Series
RefrigerantR410A
Piping Length (Total)Up to 1000 m
TypeVariable Refrigerant Flow (VRF)
Maximum Number of Indoor Units64
Coefficient of Performance (COP)Up to 4.5 (depending on model and operating conditions)
Control SystemCentralized and Individual Control
Indoor Unit OptionsCeiling Cassette, Ceiling Duct, Wall Mounted, Floor Standing
Communication InterfaceRS485
Operating Temperature Range (Cooling)-5°C to 48°C

Summary

Main PCB Ports

Compact Four-way Cassette PCB Ports

PCB port details for the Midea Compact Four-way Cassette indoor unit.

Arc Duct PCB Ports

PCB port details for the Midea Arc Duct indoor unit.

Medium Static Pressure Duct PCB Ports

PCB port details for the Midea Medium Static Pressure Duct unit.

Wall Mounted PCB Ports

PCB port details for the Midea Wall Mounted indoor unit.

Indoor Unit Settings & Functions

Parameter Settings Guide

How to configure indoor unit parameters via wired controller and unit settings.

Key Function Descriptions

Explains functions like Power Failure Memory and temperature compensation settings.

Display Panel Information

Digital Display Panel Appearance

Visual guide to display panels on different Midea indoor unit types.

Normal Operation Display Codes

Shows digital display outputs for standby and normal operating conditions.

Control System Operations

EXV Control Mechanisms

Details the Electronic Expansion Valve (EXV) operation in cooling and heating modes.

Fan & Swing Control Strategies

Covers fan speed, auto fan modes, and air swing angle adjustments.

Operation Modes & Special Features

Explains mode control, condensate pump, anti-freeze, and remote switch functions.

Error & Status Code Reference

Comprehensive Error Code List

A detailed table of error codes and their descriptions for troubleshooting.

Operating Status Code Guide

Lists and explains operating status codes for system monitoring purposes.

Troubleshooting Specific Faults

System Shutdown & Leak Detection

Diagnosing emergency shutdowns and refrigerant leaks (A01, A11).

ODU & Communication Faults

Troubleshooting ODU errors and communication failures between units (A51, C21).

Sensor & Component Failures

Addressing faults related to temperature, humidity sensors, and other components (E21, EA2).

Motor & Power Supply Issues

Resolving motor failures, power supply faults, and fan drive board problems (J01, J3E).

Appendices & Compatibility Data

Temperature Sensor Resistance Data

Table of resistance characteristics for indoor temperature sensors.

IndoorOutdoor Unit Compatibility Matrix

Compatibility information between Midea indoor and outdoor VRF units.