10-527-1 MN3024DIY REV A
MN3024DIY
User Manual
Parameter
no.
Parameter
name
Settings Description
06
Charger
source
priority
[06] CSO
PV priority charging; when not PV is unavailable,
charging from the mains is started.
[06] CUB
Mains priority charging; When charging from the
mains is not available PV charging is started.
[06] SNU default
PV and Mains hybrid charging; PV charging is a
priority, and when the PV energy is insufficient,
the Mains charging supplements. When the PV
energy is sufficient, the Mains charging stops.
Note: Only when the Mains bypass output is
loaded, the PV charging and the mains
charging can work at the same time. When the
inverter is in use, only the PV charging can be
started.
[06] OSO
Only PV charging, with the Mains charging not
activated.
07
Max charger
current
[07] 80A default
Max charger current (AC charger+PV charger).
Setting range: 0~140A
08 Battery Type
[08] USE User-defined; all battery parameters can be set.
[08] SLd
Sealed lead-acid battery;
absorption charge Voltage: 28.2,
float charge voltage: 27.6V
[08] FLd
Vented lead-acid battery;
absorption charge voltage: 29.2V,
float charge voltage: 27.6V
[08] GEL default
Colloidal lead- acid battery;
absorption charge voltage: 28.4V
float charge voltage: 27.6V
;
[08]
LF07/LF08/LF09
Lithium iron phosphate battery LF07/LF08/LF09,
corresponding to 7 strings ,8 strings and
9 strings
of lithium iron phosphate battery; for 7
strings,
default absorption charge voltage
is 24.8V; for 8 strings,
default absorption
charge voltage is 28.4V; for 9 strings, default
absorption charge voltage is 31.8V adjustable