6 – Error Codes xRC-3363
E r ro r D e s c r ip t io n E r r o r C o d e E r ro r M e s s a g e
12V Fuse Fault 13 Detected 12V fuse open. Fuse is located behind fuse
door on back of charger. Unplug unit from wall outlet
prior to removing fuse door.
Replacement fuse: 8A 400V Type 3AB.
MFG.: SCHURTER INC., Part No.: 8020.5077.
Contact Midtronics Customer Service if additional
assistance is needed.
High Voltage Fuse Fault 14 Detected high voltage fuse open. Fuse is located
behind fuse door on back of charger. Unplug
unit from wall outlet prior to removing fuse door.
Replacement fuse: 8A 400V Type 3AB.
MFG.: SCHURTER INC., Part No.: 8020.5077.
Contact Midtronics Customer Service if additional
assistance is needed.
Grounding Fault 15 Internal Error. Contact Midtronics Customer Service.
Internal Circuit Fault 16 Internal Error. Contact Midtronics Customer Service.
Internal Communication
Error
17 Internal Error. Contact Midtronics Customer Service.
Battery Pack
Communication Error
18 Cannot communicate with BECM. Verify correct low
voltage harness used and properly connected. After
verifying connections, if issue persists, disconnect
charger,and check for BECM DTCs using a Scan Tool.
Diagnose as necessary. If BECM communicates with
Scan Tool contact Midtronics Customer Service for
additional assistance.
Internal Temperature
Too High
19 Charger over temperature condition detected. Verify
airow around unit is not blocked, and that the fan is
rotating. Contact Midtronics Customer Service if issue
persists.
Internal Memory Fault 20 Internal Error. Contact Midtronics Customer Service.
Internal EEPROM Fault 21 Internal Error. Contact Midtronics Customer Service.
Internal Calibration Fault 22 Internal Error. Contact Midtronics Customer Service.
Internal Circuit Fault 23 Internal Error. Contact Midtronics Customer Service.
Internal Circuit Fault 24 Internal Error. Contact Midtronics Customer Service.
Battery Polarity Fault 25 Battery voltage polarity incorrect. Check battery
cable voltage connection leads. If issue persists,
contact Midtronics Customer Service.
Cable Error 26 The cables are not properly connected, or the
cables are damaged. Verify all low and high voltage
connections and try again. If issue persists, contact
Midtronics Customer Service for additional assistance.