Problem Possiblecause Remedy
Thefanisnotrunning. Steamisnotbeing
used.
Thefanonlyrunsifsteamis
requestedviatheiron.
Thesteamfunction
isnotreadyyet.
Wait until the indicator light *
comes on to signal that the steam
function is ready for use.
Thewatercontainer
isemptyornot
fitted.
Fillthewatercontainerwithfresh
tapwaterandfititinthetower.
Thesteameris
connected.
The fan only operates if the iron is
connected.
Plug in the iron.
Theironingboardis
notlockedinto
placeonbothsides
ofthetower.
Ensuretheironingboardis
lockedintoplaceon both sides
ofthetower(see'Assembling').
Thereisafaultwith
thesteamironing
system.
CallMiele.
Thedescalingprocess
cannotbestarted
althoughtheindicator
light k isflashingor
illuminated.
Theironorthe
steamerisplugged
in.
Unplugtheironorthesteamer
fromthesteamconnection
socket.
Thebutton j was
pressedtoobriefly.
Pressandholdthebutton j for
longer.
Thereisafaultwith
thesteamironing
system.
CallMiele.
Problemsolvingguide
63