Operating instructions
Washer-disinfector
G 7836 CD
To avoid the risk of accidents or
damage to the machine it is
essential to read these instructions
before it is installed, commissioned
and used for the first time.
G
M.-Nr. 06 507 991

Table of Contents

Other manuals for Miele G 7836 CD

Question and Answer IconNeed help?

Do you have a question about the Miele G 7836 CD and is the answer not in the manual?

Miele G 7836 CD Specifications

General IconGeneral
BrandMiele
ModelG 7836 CD
CategoryWasher
LanguageEnglish

Summary

Description of the machine

Areas of application

Lists various medical and laboratory products suitable for cleaning.

Parameters for thermal disinfection

Details thermal disinfection temperatures and holding times for HBV inactivation.

Guide to the machine

Electronic controls

Explains the function of display, on/off, cursor, minus, plus buttons.

Electronic controls continued

Explains start and stop buttons, service interface, and programme selector.

Machine components overview

Identifies key parts of the washer-disinfector with numbered labels.

Warning and safety instructions

Correct use

Specifies intended use and restrictions for the washer-disinfector.

Installation and servicing safety

Emphasizes commissioning and maintenance by qualified personnel.

Personnel and chemical handling safety

Covers training, chemical handling, protective gear, and general precautions.

High temperature and electrical safety

Warns about hot surfaces, heating elements, and electrical disconnection.

Quality standards and disinfection parameters

Stresses routine confirmation of cleaning standards and disinfection parameters.

Chemo-thermal disinfection and theatre shoes

Details chemo-thermal use, suitability for theatre shoes, and monitoring.

Chemical agent usage and compatibility

Advises on approved agents, foam creation, and critical application discussions.

Mobile units and hollow instruments

Covers proper use of accessories and cleaning of hollow instruments.

Chemical residue avoidance and installation advice

Warns against acid/solvent residues and emphasizes following installation instructions.

Using accessories and disposal of old machine

Discusses genuine accessories, disposal procedures, and safety during disposal.

Opening and closing the door

Electro-thermal door lock

Explains the automatic door locking mechanism and conditions for opening.

To open the door with the emergency release

Details the procedure for opening the door in case of a power failure.

Water softener

Setting the water softener

Explains the need for soft water and how the softener is set.

Reactivation display

Describes the display message for softener salt depletion and reactivation.

Reactivating the water softener

Specifies the type of salt to use and precautions for filling the salt container.

Filling the salt container

Step-by-step guide on how to fill the salt container.

Position the salt container as follows

Illustrates how to correctly position the salt container.

Run the reactivation programme

Outlines the steps to run the reactivation programme and post-programme actions.

Automatic mobile unit recognition (AWK)

AWK system overview

Explains how the AWK system allocates programmes to mobile units.

Pre-programme check for AWK

Emphasizes checking the displayed programme matches the mobile unit.

Mobile unit coding

Details how mobile units are coded using a magnetic strip and bits.

Mobile unit coding strip

Shows the coding strip layout and possible code assignments.

Setting mobile unit coding

Step-by-step guide to setting or altering mobile unit coding.

Setting programme place coding

Illustrates setting programme place coding and placing the magnetic strip.

Areas of application

General loading checks

Lists visual checks to perform before starting a programme.

Post-programme checks

Details checks to carry out at the end of each programme for cleanliness.

Loading the machine

Provides guidelines on arranging items for optimal cleaning.

Preparing the load and unloading instruments

Instructions for emptying containers and unloading instruments.

Water connection spring adapter

Ensures correct engagement of the water connection spring adapter.

Height adjustable top basket

Explains how to adjust the top basket for different item heights.

Surgical instruments (OP)

Specific guidance for cleaning and disinfecting surgical instruments.

Anaesthetic instruments (AN)

Procedures for thermal and chemo-thermal disinfection of anaesthetic instruments.

Baby bottles (BC)

Guidelines for processing baby bottles and teats.

Operating theatre shoes (OS)

Instructions for cleaning and disinfecting operating theatre shoes.

Laboratory glassware (LG)

Guidance on cleaning and loading various types of laboratory glassware.

Dispensing liquid chemical agents

Standard and optional dispensers

Details the standard and optional dispensing systems and their capacities.

OXIVARIO kit

Information on the OXIVARIO kit for hydrogen peroxide dispensing.

Preparing the DOS dispensers

Instructions on filling containers and handling chemical agents.

Fill the containers with the relevant agent

Step-by-step guide for filling the liquid chemical agent containers.

Venting the dispensing system

Procedure for venting the dispensing system after initial setup or dry runs.

Dispensing system maintenance

Recommends periodic maintenance by a Miele approved service technician.

External Dispensing systems

Advice on using external pumps and following Programming Manual instructions.

Operation

Changing the operating level

Instructions on how to select and change operating levels (A, B, C, D).

Starting a programme

Details methods for starting programmes in fixed and free selection modes.

C. AWK – Automatic mobile unit recognition

Steps for operating the machine using the AWK system.

Programme sequence

Explains programme start, end, and display lighting behaviour.

Switching off

Procedure for safely switching off the machine.

Cancelling a programme

Instructions on how to cancel programmes in specific operating levels.

Interrupting a programme

Details on how to interrupt programmes and potential consequences.

Data transfer

Connecting to printer or PC

Information on the serial interface and connecting external devices.

Maintenance

Periodic checks

Outlines mandatory periodic inspections by a service technician.

Operational tests during maintenance

Lists tests performed as part of the maintenance procedure.

Process validation

Emphasizes user confirmation of disinfection standards and safety checks.

Routine checks

Daily checks to be performed by the user before operation.

Cleaning the filters in the wash cabinet

Instructions for cleaning the coarse filter to prevent clogging.

Cleaning the fine, flat and micro-fine filters

Steps for removing and cleaning the finer filter elements.

Cleaning the spray arms

Guidance on cleaning spray arms to ensure proper water distribution.

Cleaning the control panel and front of the machine

Methods for cleaning the control panel and machine front.

Cleaning the wash cabinet and door seals

Instructions for cleaning the wash cabinet interior and door seals.

Protein test

Recommends period protein tests to verify cleaning results.

Mobile units, baskets and inserts

Daily checks for the proper functioning of accessories.

Drying unit (TA) - Maintenance

Information about maintenance for the drying unit.

Changing the coarse filter

Steps to change the coarse filter in the drying unit.

Changing the fine filter

Instructions for changing the fine HEPA filter in the drying unit.

Printer (optional) - Renewing paper roll and colour cassette

Procedures for replacing paper rolls and colour ribbons in the optional printer.

Problem solving

Thermal cut-out

Explains the heater limiter and how to reset it after overheating.

Cleaning the filters in the water inlet

Guide to cleaning filters at the water inlet to ensure proper flow.

After sales service

Contacting Miele Service Department

Advice on troubleshooting and when to contact Miele Service.

Installation

Machine installation and levelling

General guidelines for installing and levelling the machine.

Electrical connection

Electrical safety and connection requirements

Details electrical work safety, connection standards, and earthing.

Plumbing

Connection to the water inlet

Instructions for connecting to cold, hot, and AD water supplies.

AD water connection (pressurised and non-pressurised)

Specifics for connecting to AD water supplies, including optional conversion.

Drainage

Guidelines for connecting the drainage system and hose requirements.

Technical data

Machine specifications and parameters

Lists technical details like dimensions, voltage, water pressure, and noise level.

Special features - OXIVARIO

Description of the OXIVARIO process

Explains the OXIVARIO process and its applications.

Areas of application for OXIVARIO

Details suitability for surgical instruments and sensitive items.

Connecting the H2O2 solution container

Instructions for connecting the hydrogen peroxide solution container.

Disposal of your old appliance or machine

Environmental and safety disposal procedures

Guidelines for safe and environmentally friendly disposal of the old machine.

Related product manuals