Jet table
When converting to liquid gas, the
main jets and the small jets on all
burners have to be changed.
Screw in the new jets according to
the following table.
For U.K. and IE
Main
jet Ø
Small
jet Ø
Natural gas H
Small burner
Medium burner
Large burner
Wok
0.76
1.00
1.29
1.29 /
0.63
0.39
0.42
0.54
0.80
Liquid gas
Small burner
Medium burner
Large burner
Wok
0.50
0.65
0.85
0.97 /
0.37
0.23
0.32
0.40
0.54
The jet markings refer to 1/100 mm of
the jet diameter.
Contact your local gas supplier if the
natural gas connection pressure is less
than 18 mbar or higher than 25 mbar.