USER’S MANUAL MIG
____________________________________________________________________
____________________________________________________________________________________
MATT di LIEVORE SRL Via Bianche 7 36010 Carre( VI ) Tel. 0445 / 892223 Fax 0445 / 390346
OPERATING MODES
CONDOMINIUM AUTOMATIC:
The gate is opened when the START button is pressed whether the gate is
closed or being closed. The START command is ignored while the gate is being
opened, whereas during the pause phase it makes the timing of this phase
restart. After pressing STOP, pressing START closes the gate.
SUPERAUTOMATIC:
The gate is opened when the START button is pressed whether the gate is
closed or being closed. While the gate is being opened however it produces a
STOP, after which a subsequent START closes the gate. During the pause phase,
pressing the START button closes the gate. After pressing STOP, pressing START
closes the gate.
AUTOMATIC:
The gate is opened when the START button is pressed whether the gate is
closed or being closed. The START command is ignored while the gate is being
opened, whereas during the pause phase it makes the gate close again. After
pressing STOP, pressing START closes the gate.
SEMIAUTOMATIC:
The START button controls the opening, closing and halting of the gate. After it
is opened, it is necessary to press the START button to close it again. While the
gate is being opened, pressing START halts the gate and another pulse makes
the gate close. If START is pressed during the closing phase the direction is
inverted. After pressing STOP, pressing START closes the gate.
STEP BY STEP:
The gate is opened when START pulse is pressed while the gate is closed.
The START command produces a STOP during the opening phase, subsequently
pressing START causes the gate to close, and pressing START again produces a
STOP. After pressing STOP, pressing START closes the gate.