REMOTE CONTROLS LEARNING
The SR equipment is equipped with a built-in decoder able to memorize up to 128
rolling-code remote controls or one fixed-code remote controls.
Start function
In closed-gate mode, press the P2 button and hold it down until the TEST LED starts
to flash. Release the P2 button.
Within 10 seconds, set the remote control button that you want to connect to the
START command. The completion of the process will be indicated by the
simultaneous flash of the TEST LED, of the flasher and of the pilot lamp, followed by
the termination of the flashing of the TEST led.
With rolling code remote controls, repeat the process for each remote control to
be set. With fixed-code remote controls it is sufficient to carry out the process for
only one model.
Pedestrian start function
In closed-gate mode, press the P2 button and hold it pressed until the TEST led
starts to flash; don’t release the button and wait until the flashing speeds up.
Release the P2 button.
Within 10 seconds set the button of the remote control to learn and to be
connected with the PEDESTRIAN START control. When the learning has been
carried out it will be indicated by the simultaneous flash of the TEST led, flasher
and of the pilot lamp, followed by the termination of the flashing of the TEST led.
In case of rolling code-type remote controls repeat the operation for each remote
control to learn. In case of fixed-type remote controls it is sufficient to carry out the
learning of one single model.
Complete erasing of all learnt remote controls
In closed-gate mode, press the P2 button and hold it pressed till when the TEST led
starts to flash; don’t release the button and wait until the flash gets quicker; don’t
release the button and wait until the flash gets very quick; don’t release the button.
When the blanking /blackout of ALL the learned remote controls has been carried
out it will be indicated by the simultaneous flash of the TEST led, flasher and of the
pilot lamp, followed by the ending of the flashing of the TEST led.