USER’S MANUAL MIG
____________________________________________________________________
____________________________________________________________________________________
MATT di LIEVORE SRL Via Bianche 7 36010 Carre’ ( VI ) Tel. 0445 / 892223 Fax 0445 / 390346
Erasing of one learnt remote controls
In closed-gate mode, press the P2 button and hold it pressed till when the TEST led
starts to flash; don’t release the button and wait until the flash gets quicker; don’t
release the button and wait until the flash gets very quick; release the button and
push the start button on the remote controller that you want to erase by the
ending of the flashing of the TEST led you erased the remote controller.
LEARNING
WARNING the GATE has to be closed
Press the P1 learning button for at least 3 seconds, until the TEST LED
starts to flash, then do as follows:
WARNING If do not start with learning until 10 sec DL4 LED turns off and learning is
not done correctly, so you have to restart. During the learning you have to pay
attention on photocells and do not press STOP button, otherwise you have to restart
learning.
1° input START:
the gate begins to open at standard speed
2° input START:
When you decide to start the slow-stroke phase, press START: the slow-
stroke phase starts
After 3 seconds boom starts closing. the boom begins to close at standard speed