USER’S MANUAL MIG
____________________________________________________________________
____________________________________________________________________________________
MATT di LIEVORE SRL Via Bianche 7 36010 Carre’ ( VI ) Tel. 0445 / 892223 Fax 0445 / 390346
3° input START:
When you decide to start the slow-stroke phase, press START: the slow-
stroke phase starts until the limit switch
After 3 seconds gate starts opening.
4° input START:
gate stops at pedestrian point decided.
After 3 seconds gate starts closing.
Wait until the DL4 LED turns off.
Learning finished.
The subsequent maneuver will be standard within the parameters just set
If one of the normally-open inputs (START, CL/SP, OPEN) is closed, or one of the
normally-closed inputs (STOP, PHOTO, SAFETY) is open, the TEST LED flashes at
high frequency. In this case it is not possible to carry out the learning strokes
procedure. Fit a jumper cable on the normally-closed contacts when they are not in
use.