CONNECTION M1
1 OPEN
Opening if boom is down, or if boom is closing
2 START
Opening if boom is down, stop during opening if DIP 2
stopped, opening if boom is closing
3 CL/SP
Pedestrian passage with boom down, closing if boom is open
4 STOP/EM
If DIP 4 OFF stop any boom action, if activated no action
If DIP 4 ON stops any boom action, boom remains closed until command is activated
than star opening.
5 PHOTO
Opening if boom closing, if active no action.
6 SAFETY
If DIP 8 OFF change direction if boom closing, if active no action.
If DIP 8 ON Se DIP 8 ON: OFF change direction if boom closing or opening, if active
no.
7 COM Common for inputs
8 L.S.C.
Normally closed contact limit switch closing
9 L.S.O.
Normally closed contact limit switch opening.
10 COM Common for inputs
11 K OPT
Fast flashing during closing slow flashing during opening, light on if boom is open,
light off if boom closed.
supply accessories 24V CC (picture down)
12 K OPT
13 + V 24 V Positive supply accessories 24V CC
14 - V 24 V Negative supply accessories 24V CC