EasyManua.ls Logo

Migatronic PILOT 161 AC/DC - Technical Specifications

Migatronic PILOT 161 AC/DC
48 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
TECHNICAL DATA
Power source PILOT 161 AC/DC
Mains voltage
Main fuse
Efficiency
Current MMA
Current TIG
Permitted load:
at 100 % duty cycle
at 60 % duty cycle
Open circuit voltage
TIG start
Upslope
Downslope
Pregas
Postgas
Initial current
Final current
AC Balance
AC Frequency
Hot start MMA
1
Protection class
2
Application class
Standards
Dimensions (W-H-L)
Weight
1x230 V ±10%
16 A
0.85
7 – 130 A
7 – 150 A
MMA TIG
65 A 65 A
80 A 80 A
85 - 90 V
HF / Liftig
0 - 10 secs
0 - 10 secs
0.1 sec.
0 - 30 secs
0 - 100 %
= initial current
40 - 80 %
50 Hz
50 %
IP 23
S
EN60974-1
EN50199
20x34x36 cm
16 kg
1
The machine is designed for outdoor applications as it meets the demands of protection class IP23. However, it is a condition
that the machine is placed in an upright position.
2
S
The machine meets the standards which are demanded of machines working in areas where there is an increased risk of
electric shock