| MIJAR WATER TREATMENT |
| Azotowa 15b | 41-503 Chorz Poland | Tel./fax. 32 2899674 | email: export@mijar.eu | www.mijar.eu |
Incorrectly set softener performance
(regeneration frequency )
Examine the GH general hardness of water and re-set the
softener performance (use the tab. Softener capacity from
page 5)
7. Water softener
provides hard water
The salt level is the
same in brine tank
(slat level does not
decrease)
Salt has caked, swelled up and is suspended
over the water level in the brine tank
Break down manually caked salt. Prepare a brine solution in
a bucket (about 1.5 kg of salt per 6 liters of hot water and
mix to dissolve in). Pour the brine into the brine tank and
manually start the regeneration. If water after regeneration is
still hard, replace the resin. Refill the salt in the brine tank
after regeneration.
Salt level in the brine tank should always be above the water
level
Improperly connected softener
Check the softener connections. IN raw water inlet, OUT
treated water outlet (see picture 2 page 7)
Softener does not start regeneration


The control valve does not fill the brine tank
with water
See problem 12 

Open bypass
Close bypass
Lack of power during regeneration
Provide the electric power supply during regeneration
Lack of water during regeneration or not
enough water during regeneration
Provide water under proper pressure ( 2,0-6,0 bar) during
regeneration
8. Water softener
supplies not
completely softened
water
Amount of salt in the brine tank is too small
he brine tank (cabinet).
The amount of salt in the brine tank should always be above
the water level.
See problem 6,7 

See problem 6,7 
9. Excessive salt
consumption
Too much water in the brine tank
Decrease the time of refilling the water in brine tank
(unscrew the back side of steering valve)
See problem 10 "too much water in the brine tank"
Too frequent regeneration
Examine the hardness of the water and set the regeneration
frequency (use the tab. Softener capacity from page 5)
10. Too much water
in the brine tank.
Amount of water in
the brine tank reach
the level of the
overflow elbow
The device does not draw brine
See problem 11 The device does not draw brine
Drain is clogged or blocked
-Check the drain hose if it is bent, collapsed, broken or
clogged. Remove the hose from the drain pipe. Check if
nothing is blocking it. Clean the drainage, if necessary,
replace the hose
- Make sure nothing is blocking the sewage pipe, clean the
drainage