Ran out of water during regeneration, brine
got into the tank of the resin but was not
washed out of it
Manually initiate regeneration .This will allow the correct re-
regeneration
Water pressure drop or not enough water
during regeneration
Manually initiate regeneration. This will allow the correct re-
regeneration
Clogged drains, too small hose to drain
Clean outflow into drains, and DLFC restrictor
19. Water flow out
from drain Or brine
pipe after
regeneration
Foreign material in valve which unable
closing the valve completely
Clean valve, remove the foreign material from the valve
Water pressure is to high which result in
valve doesn
20. Water softener
efficiency decreased
after few months Or
years
Frequent absence of salt or too little salt in
the brine tank
Replace the resin and make sure that the amount of salt in
the brine tank will never be below the water level
Incorrectly set softener efficiency
Examine water hardness and program the regeneration
frequency (see table 1 page 5)
If there is no improvement, replace the resin for new
Increase the hardness of the water before the
softener
Examine water hardness and program the regeneration
frequency (see table 1 page 5)
If there is no improvement, replace the resin bed for new
21. Control valve
cycle continuously
Foreign materials stuck in the driving gear
Take out foreign material