8
| MIJAR WATER TREATMENT |
| Azotowa 15b | 41-503 Chorz Poland | Tel./fax. 32 2899674 | email: export@mijar.eu | www.mijar.eu |
3.1 Programming device
To program the device must be entered: The current time and Regeneration frequency
1. The current time
To set the current time, the user must press
and hold the white button (1), and
simultaneously turn the gearwheel (2) so in
the gap (3) the current time is shown* (like
on the watch). Next, release the white
button (1) so it falls back between the
gearwheel pins.
”a”- morning hours (midnight to midday) e.g. 9a=9:00 (AM)
p”- afternoon hours ( midday to midnight) e.g. 9p=21:00 (PM)
2. Regeneration frequency
Days of regeneration are set on the 12
day disk (4) .
Red arrow indicate the current day (5).
To set regeneration frequency use the pinions
(6) Each pinion represents 1 day: By lifting
up or lowering the pinions (6) set the
regeneration days. First the user has to lower
all of pinions (6) down and then lift the
pinions representing days, when the
regeneration is to be carried out.
EXAMPLE:
All pins are lift Every 2nd pin is lift Every 3rd pin is lift Every 4th pin is lift
Regeneration takes Regeneration takes Regeneration takes Regeneration takes
place every day place every 2nd day place every 3rd day place every 4th day

Related product manuals