14
| MIJAR WATER TREATMENT |
| Azotowa 15b | 41-503 Chorz Poland | Tel./fax. 32 2899674 | email: export@mijar.eu | www.mijar.eu |
12. The steering
valve does not fill
the brine tank with
water
Time of filling the brine tank with water
"Brine REFIL", is set incorrectly
Increase the time of refilling the water in brine tank (unscrew
the back side of steering valve)
The precipitate of iron in the softener
Clean the control valve and the resin.
Increase frequency of regeneration and / or duration of the
backwash
Limescale or blockage in water system
Check whether the settlement from the water did not block
the water system before the device
Entrance to control valve contaminated with
the rest of the installation works
Remove all contamination and clean driver
Clean or replace the filter
Installation pipe or hose supplying / drainage
water softener is too small diameter
Insert installation pipes or hoses with larger cross-section
Check the installation and make sure that the brine is in the
brine tank
Water with too high temperature got into the
softener
Remove the control valve and check the distribution pipe
(central pipe), the upper basket, lower basket, if necessary,
replace.
Damaged upper basket, lower basket or
distributor
Replace upper basket, lower basket or distributor
15. Continuous
leakage into sewage
systems from
control valve
Foreign bodies in the valve
Check the inside of the valve, remove impurities and check
the operation of the valve in different regeneration positions
Lack of power during regeneration
Check the power supply. Regeneration will be complete
when the power turns on. In case there is no possibility to
turn power on close the water supply to the machine until
the resumption of power supply.
16. Regeneration
takes place at the
wrong time
Incorrectly set time of the day
Set the current time of the day
Set the current time of the day
17. Interrupted Or
irregular brine
Water pressure too low Or not stable
Check and find the reason
Injector is plugged or faulty
Clean or replace injector
18. Salt taste of
soften water
The air inside unit. The air enters the resin
tank during the brine sucking
Check for leaks between the steering valve and the brine
valve (air check).
Brine valve leaking - check for leaks, check the ball in the
brine valve if it close valve tightly after completely sucked
from the brine tank.