The system is configured to use 4,5 kg of reagent per each regeneration.
Calculating the amount of softened water between regenerations:
The amount of water between regenerations is calculated according to this formula:
Z = 9000x10/y
Where
Z is the amount of softened water between regenerations
Y
An example of calculation the amount of
Z = 9000 x 10/15 = 6000 liters.
6000 liters of softened water.
TAB. 1. CAPACITY Maxi Elegant B65
The stated capacities were calculated based on standard application and machine conditions. This information
may vary according to external influencing factors (for example, fluctuating raw water quality).