Welding Amperage Range | 40 - 400 A |
---|---|
Fuel | Diesel |
Frequency | 60 Hz |
Duty Cycle | 100% |
Rated Output | 400 A at 36 V, 100% Duty Cycle |
Output Voltage Range | 14 - 40 V |
Input Voltage | Not applicable |
Input Phase | N/A (Engine Driven) |
Details hazards associated with arc welding processes, including electric shock.
Covers hazards related to the engine, including battery explosion and fuel.
Details technical specifications for welding output, power generation, and engine.
Explains duty cycle and provides guidance to prevent overheating.
Provides instructions for safe movement and placement of the welding generator.
Details methods for securely mounting the welding generator to a vehicle or surface.
Lists essential checks to perform on the engine before starting it.
Explains how to correctly connect welding cables to the output terminals.
Identifies and labels the front panel controls for CC models.
Provides detailed descriptions of each front panel control for CC models.
Identifies and labels the front panel controls for CC/CV models.
Provides detailed descriptions of each front panel control for CC/CV models.
Outlines the regular maintenance schedule and tasks for the equipment.
Describes how to adjust engine speed for idle and weld/power operations.
Guides on maintenance for the engine's fuel and lubrication systems.
Provides a guide to diagnose and resolve common welding and generator issues.
Explains grounding the generator to a vehicle frame for safety.
Guides on generator output limits and starting non-resistive loads.