EMF DATA SHEET FOR ARC WELDING POWER SOURCE
Product/Apparatus Identification
Product
Stock Number
DELTAWELD 402 380/400/440 50/60HZ CE 907357
DELTAWELD 602 380/400/440 50/60HZ CE 907358
DELTAWELD 852 380/400/440 50/60HZ CE 907359
Compliance Information Summary
Applicable regulation Directive 2014/35/EU
Reference limits Directive 2013/35/EU, Recommendation 1999/519/EC
Applicable standards IEC 62822-1:2016, IEC 62822-2:2016
Intended use ☒ for occupational use ☐ for use by laymen
Non-thermal effects need to be considered for workplace assessment ☒ YES ☐ NO
Thermal effects need to be considered for workplace assessment ☐ YES ☒ NO
☒ Data is based on maximum power source capability (valid unless firmware/hardware is changed)
☐ Data is based on worst case setting/program (only valid until setting options/welding programs are changed)
☐ Data is based on multiple settings/programs (only valid until setting options/welding programs are changed)
Occupational exposure is below the Exposure Limit Values (ELVs) ☒ YES ☐ NO
for health effects at the standardized configurations (if NO, specific required minimum distances apply)
Occupational exposure is below the Exposure Limit Values (ELVs) ☐ n.a ☒ YES ☐ NO
for sensory effects at the standardized configurations (if applicable and NO, specific measures are needed)
Occupational exposure is below the Action Levels (ALs) at the ☐ n.a ☐ YES ☒ NO
standardized configurations (if applicable and NO, specific signage is needed)
EMF Data for Non-thermal Effects
Exposure Indices (EIs) and distances to welding circuit (for each operation mode, as applicable)
Head
Trunk
Limb (hand) Limb (thigh)
Sensory Ef
fects
Health Ef
fects
Standardized distance 10 cm 10 cm 10 cm 3 cm 3 cm
ELV EI @ standardized distance 0.32 0.07 0.11 0.06 0.14
Required minimum distance 2 cm 1 cm 1 cm 1 cm 1 cm
Distance where all occupational ELV Exposure Indices fall below 0.20 (20%) 19 cm
Distance where all general public ELV Exposure Indices fall below 1.00 (100%) 128 cm
Tested by: Tony Samimi Date tested: 2016-02-10
275665-A