OM-1585 Page 22
7-2. Dual Schedule Switch Diagrams
1 Momen 2P
(Momentary-Contact 2-Pole
Switch)
2 Maint 2P (Maintained-Contact
2-Pole Switch)
3 Maint 1P (Maintained-Contact
1-Pole Switch)
4 Trigger
Allows dual scheduling after
establishing a welding arc.
. If trigger is used for dual sched-
ule switch, Trigger Hold is dis-
abled.
11
22
33
4
1
2
3
4
B
A
TR
3
Adapter
11
22
3A
4B
1
11
22
3A
4B
2
1
2
TR
4
SECTION 8 − USING THE OPTIONAL DATA CARD
8-1. Data Card Terms
SA-158 435
>Wr i t e
Read
De l e t e
Done
READ Programs From Card
WRITE Programs To Card
CARD SCREEN TERMS
PULSE MIG TERMS
PPS
(Pulses Per
Second)
Apk (Peak
Amperage)
PWms
(Pulse Width In
Milliseconds)
Abk
(Background
Amperage)
Time
Amperage