Air Supply System
Milltronics machining centers require a constant supply of quality air pressure in order to
perform optimally. 90-110 PSI at 10 CFM is required for RW15-20 and RH19-30
models.
Adjustments
Do not adjust the air purge regulator unless instructed to do so by an authorized
Milltronics Representative.
Set the drop rate on the lubricator to approximately 1 drop per every 1-2 tool
changes
Spindle air pressure
gauge. Do not alter
from factory setting.
Maintain fill
levels weekly
using specified
air tool oil.
Main air pressure
gauge. Adjust
using knob “A”.
90 PSI
A
B
Water trap is self-
draining. No need
to drain manually.
Fill with Marvel
No.085, Mobil
Velocite No. 10
or equivalent.