C
HAPTER
6 - M
AINTENANCE
39
enclosure door to verify that the spindle brakes rapidly to a stop and machine
motion is halted.
Air System Maintenance
Ensure the air lubrication unit dispenses oil, and that the oil reservoir fill level is
maintained. (Use Marvel No. 085, Mobil Velocite No. 10 or equivalent oil, further
details about lubrication type can be found in the mechanical manual)
Ensure the automatic water trap drain is working.
Adjustments
Do not adjust the air purge regulator unless instructed to do so by an authorized
Milltronics Representative.
Set the drop rate on the lubricator to approximately 1 drop per every 1-2 tool
changes
Spindle air pressure
gauge. Do not alter
from factory setting.
Maintain fill
levels weekly
using specified
air tool oil.
Main air pressure
gauge. Adjust
using knob “A”.
90 PSI
A
B
Water trap is self-
draining. No need
to drain manually.
Fill with Marvel
No.85, Mobil
Velocite No. 10
or equivalent.