6.1 Installation area.
This actuator is an explosion-proof equipment and can be used in the
following areas:
EPL = Equipment’s Protection Level. b= high level Gas (G) and Dust
(D).
Zone 1 (gas): the explosive atmosphere is likely to occur occasionally
in normal operation.
Zone 2 (gas): the explosive atmosphere is not likely to occur in normal
operation but if it does occur, it will persist for a short period of time
only.
Division 1: the explosive atmosphere is likely to occur during periodic
maintenance or during normal operation.
Division 2: the explosive atmosphere is not likely to occur in normal
operation but in case of accidental rupture or abnormal operation.
!
This device has not been designed to be operated in an area
where explosive atmosphere occurs frequently or during long
periods (IEC 79
-
10
-
zone 0).
Actuator type ACC (IECEx + ATEX) AQX L (CSA)
Protection
class
Ex db
Class I Group C, D
Class II
Group E, F, G
C
lass III
C
ategory
2 (EPL Gb)
Division
Zone 1 or 2 Division 1 or 2
Atmosphere
G Gas Gas Dust