Please record the following data for file reference
Tag Number(s): _____________________________________
Model Number: _____________________________________
Serial Number: _____________________________________
Installation Date: ____________________________________
Installation Location: ________________________________
Electronic
Capacity Control
maxRoy
®
B, MacRoy
®
, mRoy
®
, and Milroyal
®
Product Family Pumps
339-0083-000
ISSUED 01/2012
This manual supersedes the following manuals:
339-0002-000, 339-0006-000, 339-0016-000,
339-0018-000, 339-0051-000, 339-0067-000, and 339-
0083-000 Dated 08/2005 & 09/2009
INSTALLATION,
OPERATION, AND
MAINTENANCE
MANUAL
mRoy
www.motralec.com / service-commercial@motralec.com / 01.39.97.65.10

Table of Contents

Questions and Answers

  • J
    John ClaytonAug 4, 2025
    What to do if my Milton Roy Water Pump ECC chatters or vibrates?
    • R
      Robert ConnerAug 4, 2025
      If your Milton Roy Water Pump's ECC chatters or vibrates, and the limits are okay, the circuit board or feedback potentiometer might need replacing. Otherwise, the ECC could be driving the pump adjustment against its mechanical stop. In this case, reset the ECC and the pump's high and low limits according to the calibration procedure.
  • B
    bowerscrystalAug 9, 2025
    Why is my Milton Roy Water Pump ECC not responding to the 4-20 mA command signal?
    • J
      Jeffrey MartinAug 9, 2025
      If the ECC on your Milton Roy Water Pump isn't responding to the 4-20 mA command signal, first ensure the ECC is receiving AC power. If not, apply power. Next, check the polarity of the 4-20 mA signal wires connected to the terminals and correct if improperly connected. If the motor is frozen, with the power off, use the handwheel to check its rotation and replace the motor if needed. You may also need to replace the potentiometer or the PC board.
  • W
    William MccartyAug 16, 2025
    What to do if limit lights flicker as ECC moves in Milton Roy Water Pump?
    • L
      lisamendozaAug 16, 2025
      If the limit lights flicker as the ECC moves on your Milton Roy Water Pump, it could be due to a bad feedback potentiometer. Use an oscilloscope to observe the pot signal while it's in motion; if necessary, replace the feedback potentiometer assembly. Another cause could be a bad connection at the plugs, so check the continuity and repair or replace plugs and/or wiring as needed. Finally, a bad printed circuit board could also be the culprit, requiring replacement of the PC board.
  • C
    charlesgeorgeAug 22, 2025
    Why my Milton Roy Water Pump ECC will only travel in one direction?
    • M
      Matthew KingAug 22, 2025
      If the ECC on your Milton Roy Water Pump only travels in one direction, the printed circuit board is likely faulty and needs to be replaced.
  • M
    Maurice WeaverAug 28, 2025
    How to troubleshoot ECC moving to the same position on Milton Roy Water Pump?
    • M
      Melissa WoodAug 28, 2025
      If the ECC on your Milton Roy Water Pump consistently moves to the same position regardless of the signal applied, first check the command signal being applied to the ECC. Connect a mA meter into the signal line to read the signal and correct the signal source if necessary, checking for broken wires or loose connections. Also, review the initial start-up procedure to ensure the mode setup is correct. Finally, the feedback potentiometer gear may be slipping or worn. Manually move the knob, apply a control signal, and observe the gear; if necessary, replace the feedback potentiometer assembly.

Summary

PRECAUTIONS

Safety Precautions

Covers protective clothing, hearing, electrical safety, liquid compatibility, and general safety.

IMPORTANT SAFETY INSTRUCTIONS

General Safety Considerations

Covers general safety advice for installation, calibration, and maintenance.

QUICK START GUIDE

SECTION 2 - INSTALLATION

Initial Information and Handling

Covers general info, unpacking, storage, and field installation guidelines.

Safety and Mounting

Details on installation safety precautions and mounting the ECC.

Electrical Connections and Wiring

Guidance on connecting signals, power, and wiring requirements.

Circuit Board Retrofit Procedures

Steps for replacing or retrofitting ECC circuit boards.

SECTION 3 - OPERATION

SECTION 4 - MAINTENANCE

Parts, Returns, and General Maintenance

Covers spare parts, returning units, and basic maintenance needs.

PCB Replacement Procedures

Detailed steps for removing and installing ECC circuit boards.

Potentiometer and Gear Replacement

Instructions for replacing feedback potentiometers and nylon worm gears.

SECTION 5 - TROUBLESHOOTING

Milton Roy MAXROY B Specifications

General IconGeneral
BrandMilton Roy
ModelMAXROY B
CategoryWater Pump
LanguageEnglish

Related product manuals