EasyManua.ls Logo

Milton Roy mRoy B - User Manual

Milton Roy mRoy B
79 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
mRO
Y
®
A & B
Metering Pump IOM Manual
Manual No : 54649
Rev. : 03
Rev. Date : 5/2019
Original Version

Table of Contents

Questions and Answers

  • L
    Lori FoxAug 4, 2025
    What to do if my Milton Roy Water Pump is making a pounding noise at high discharge pressure?
    • C
      cmoranAug 4, 2025
      The pounding noise at high discharge pressure in the drive casing is due to fluid compressibility causing a reversal load on the gears at the end of the pressure stroke. This is not considered detrimental, so no action is needed.
  • S
    Stacy GomezAug 11, 2025
    Why does my Milton Roy mRoy B motor overheat and trigger thermal overload switches?
    • P
      pkingAug 11, 2025
      The motor overheats and triggers thermal overload switches for the following reasons: the power supply does not match the motor characteristics, so you should check the power supply against the motor nameplate data. Another reason might be overload caused by operating the pump above its discharge pressure, so you should check the operating pressure against the pump manufacturer’s data plate max. rating and correct the cause of the pressure abnormality.
  • C
    Christine HerreraAug 19, 2025
    What to do if my Milton Roy Water Pump delivery is not adjustable?
    • T
      Tiffany BoyleAug 19, 2025
      If your Milton Roy Water Pump delivery is not adjustable, consider the following: the flexible diaphragm may be punctured by foreign material, requiring you to replace the diaphragm; the O-rings on the control spool may be nicked, requiring you to replace the O-rings (note: you must use a special tool).
  • J
    Jeffrey DavisNov 25, 2025
    What to do if my Milton Roy mRoy B Water Pump is too noisy?
    • M
      Mary WashingtonNov 25, 2025
      Pump valves must move to open and close, and they will make a clicking noise as they operate. These noises are sometimes amplified by natural resonances in the piping system. They are usually indications of normal valve functioning. If the pump internal relief valve is actuating, this can be caused by several issues. It may be due to excessive suction lift conditions, so you should lower the pump or raise the level of liquid. It may be due to insufficient suction pressure, so you should correct the poor suction condition. It may be due to a clogged or partially blocked filter or strainer in the suction line, so you should clean the strainer. It may be due to clogged or fouled suction or discharge check valves, so you should clean or replace them. Finally, it may be due to a blocked dischar...

Summary

Precautions

Protective Clothing

Wear OSHA-approved protective clothing, face shield, safety glasses and gloves.

Section 2 - Installation

Piping and Suction Lift

Guidelines for piping, suction lift, and NPSH requirements.

Section 3 - Operation

Initial Start-Up and Priming

Steps for initial pump start-up, including torque checks, oil levels, and priming.

Section 4 - Maintenance

Routine Maintenance Tasks

Regular maintenance like cleaning, leak checks, oil level checks, and valve replacements.

Section 5 - Troubleshooting Guide

Motor and Capacity Issues

Symptoms and remedies for motor and pump capacity problems.

Section 6 - Parts

mRoy A Parts Lists

Detailed parts lists for mRoy A models, including motor mounts and liquid ends.

mRoy B Parts Lists

Detailed parts lists for mRoy B models, including motor mounts and liquid ends.

Model Code Selection and Components

Guide to selecting model codes and understanding component options.

Milton Roy mRoy B Specifications

General IconGeneral
BrandMilton Roy
ModelmRoy B
CategoryWater Pump
LanguageEnglish

Related product manuals