4.2.4 P.1
1
2
3
4
5
6
7
8
R.1.0
Maintenance Manual > Adjustment Items > Adjustment Function > MEDIA COMP.2
Model CJV30/TPC Issued 2008.08.04 Revised F/W ver. 1.00 Remark
1.0
Rev.
4.2.4 MEDIA COMP.2
Function
Compensates basic feeding amount of media. (Provides a baseline value for user compensation value.)
Is used to adjust the media feed amount when the parameter has been initialized or user compensation value is too large.
Procedure
1. Select [MEDIA COMP.2] from the operation menu.
2. Draw an adjustment pattern.
[ENTER]: Executes drawing.
[]: To the screen for adjustment
(Without drawing)
[END]: Completes drawing and inputs compensation
value.
3. Check the adjustment pattern.
4. Enter the compensation value.
Compensation value: -500 to 500
[]/[]: Changes adjustment values.
[END]: Cancellation of input
<LOCAL.> [#01]
FUNCTION
#ADJUST <ent>
#ADJUST / PRINT
MEDIA COMP.2 <ent>
#MEDIA COMP.2
PRINT START :ent
Pattern drawing
Patterns are plotted repeatedly.
(Click [END] to end plotting.)
A pattern having width
of media is drawn.
Resolution is 720 dpi.
Compensation value is
too large.
Compensation value is
too small.
#MEDIA COMP.2
VALUE
In actual feeding amount compensation, compensation
value for each media set in the SETUP function are
added to this compensation value.