EasyManua.ls Logo

MIMAKI CJV30-100 - Page 136

MIMAKI CJV30-100
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2009 MIMAKI ENGINEERING CO.,LTD.
5.1.5 P.1
1
2
3
4
5
6
7
8
R.1.2
Maintenance Manual > Test Items > Test Function > [MOTOR TEST] X SERVO MOTOR
Model CJV30/TPC Issued 2008.08.04 Revised 2009.06.30 F/W ver. 1.20 Remark
1.2
Rev.
5.1.5 [MOTOR TEST] X SERVO MOTOR
Function
Operation test of X-axis motor is executed.
Operation Procedures
Step Item Description Remarks
1 Speed designation [], []: Selects speed.
Set value: 1 – 500 mm/s (unit: 1 mm/s)
[], []:
Selection of item 2 – 4
2 Acceleration designation [], []: Selects acceleration.
Set value: 0.01 – 2.00 G (unit: 0.01 G)
3 Moving amount designation [], []: Selects moving amount.
Set value: 1 mm – media length (width) (unit: 1 mm)
When media is not detected: 1 mm – Mechanical
limit size
4 Test start [ENTER]: Repeats reciprocating motion in the X direction
with designated conditions.
5 End [END]: Returns to the motion starting position and
executes capping to end the test.
During the test, heater temperature control is allowed. (When [HEATER] key is effective)

Other manuals for MIMAKI CJV30-100

Related product manuals