Maintenance Manual >Troubleshooting > Detailed Methods of Coping with the Malfunctions > Media Attachment to the
Model CJV30/TPC Issued 2008.12.06 Revised F/W ver. 1.00 Remark
1.0
Rev.
7.2.2 Media Attachment to the Platen
Outline
Some media may attach to the platen and cause the X overcurrent error.
To avoid the problem, tape the Niftron tape on to the platen as the following procedures.
Tools
Niftron tape (Model: No.973UL-S 0.13mm x 10mm x 10m, company: NITTO DENKO)
Scissors
Ethanol (alcohol) or diluted mild detergent to remove dirt and oil.
Paper towel to remove dirt and oil. (lint-free towel such as BEMCOT)
Procedure
1. Remove oil on the platen with ethanol or diluted mild detergent.
(Use BEMCOT)
2. Tape the Niftron tape (5 places, cut with scissors) on the platen.
Make sure to turn off the main switch to prevent unexpected movements of the printer..
Niftron Tape
Be careful not to cover the vacuum hole with the tape.
It is acceptable that the tape touches the edge of the
hole.