8.5.2 P.1
1
2
3
4
5
6
7
8
R.1.0
Maintenance Manual > Operation Flow > Service Mode > #TEST
Model CJV30/TPC Issued 2008.08.04 Revised F/W ver. 1.00 Remark
1.0
Rev.
8.5.2 #TEST
#CHECK PATTERN
PATTERN:100%
DPI :540x720
SCAN:Uni-D / PASS:6
#CHECK PATTERN
PATTERN:COLOR CHART
DPI :540x720
SCAN:Uni-D / PASS:6
X=1000 Y=1000
DENSITY :ALL
#TEST
CHECK PATTERN <ent>
[] / []
FUNCTION
#TEST <ENT>
[ENTER] / [END]
[] / []
X=1000 Y=1000
COLOR :KMCY
#CHECK PATTERN
PATTERN:DROP.POS CHK
DPI :540x720
SCAN:Uni-D / PASS:6
X=1000 Y=1000
[] / []
#CHECK PATTERN/100%
PRINT START :ent
540x720.V6. 6P,Uni
x1.H1 0.00m
DPI: 540x720.PAS: 6
SCN:Uni SPD:x1 WF:6
HED:1 CL:MCYK1234
X=10 Y=10
#CHECK PATTERN/100%
Hi-SPEED SCAN :OFF
Subsequently, 50%, 25%, 12.5%, 6.25%,
nozzle check can be selected (Omitted).
JOG permitted
[FUNCTION]
[REMOTE]
#TEST
ALL PATTERN <ent>
[] / []
#ALL PATTERN
PRINT START :ent
[] / []
#TEST
MOTOR TEST <ent>
#MOTOR TEST
X SERVO MOTOR <ent>
#X SERVO
RUNNING
COUNT = 0
#X SERVO MOTOR
S= 500 A=0.50 X=1000
#MOTOR TEST
Y SERVO MOTOR <ent>
#Y SERVO
RUNNING
COUNT = 0
#Y SERVO MOTOR
S= 500 A=0.50 X=1000
Pressing [HEATER/CUTTER] displays
the heater control screen.
#MOTOR TEST
XY SERVO MOTOR <ent>
#XYservo
RUNNING
COUNT = 0
S= 500 A=0.50 X=1000
S= 500 A=0.50 X=1000
#MOTOR TEST
WIPER MOTOR <ent>
#WIPER
RUNNING
COUNT = 0
SPEED :WAIT :COUNT
100 : 0 :CONT.
#WIPER
RUNNING
100 : 0 :CONT.
[] / []
#MOTOR TEST
PUMP MOTOR <ent>
#PUMP MOTOR
COUNT = 0
#PUMP MOTOR
SPD=1200 DIR=FORW.
[] / []
<CARRIDGE>:< MOTOR >
IN : OFF
S= 500 A=0.50 X=1000
S= 500 A=0.50 X=1000
[] / []
#Y SERVO
RUNNING
S= 500 A=0.50 X=1000
[] / []
[] / []
#X SERVO
RUNNING
S= 500 A=0.50 X=1000
[] / []: Changes condition display.
[]/[]: Modifies the compensation value.
[ENTER]: Finalizes (To the next compensation screen)
Pattern drawing
[] / []: Changes condition display.
[] / []: Changes condition display.
[] / []: Changes condition display.
Pressing [HEATER/CUTTER] displays
the heater control screen.
Pressing [HEATER/CUTTER] displays
the heater control screen.