94
Item Function No. Setting value Contents
Judge condition SQF-30
0
Timer is up
1 Stable and timer is up
2 Stable or timer is up
Waiting time for judge SQF-31
0000 ~ 9999
0000
Unit0.01s
0000Waiting time for judge OFF
Maximum time of
compensation flow
SQF-35
000to255
000
Unit1time
000compensation flow OFF
Judge condition after
compensation flow
SQF-36
0
Timer is up
1 Stable and timer is up
2 Stable or timer is up
Compensation flow time SQF-37
0000 ~ 9999
0000
Unit0.01s
0000Compensation flow OFF
Waiting time for judge
after compensation flow
SQF-38
0000 ~ 9999
0000
Unit0.01s
0000 Waiting time for judge after
compensation flow OFF
Output time for the Batch
finish signal
SQF-40
0000 ~ 9999
0000
Unit0.01s
0000 Output time for the Batch finish
signal OFF
Batch finish output OFF SQF-41
0
No condition
1 OL or unstable
2 Near zero
Discharge start at the
time batch finish
SQF-45
0
Invalid
1 Effective
Discharge monitor timer SQF-46
0000 ~ 9999
0000
Unit1s
0000Discharge monitor OFF
Discharge gate close
delay time
SQF-47
0000 ~ 9999
0000
Unit0.01s
0000 Discharge gate close delay time
OFF
Discharge finish output
time
SQF-48
0000 ~ 9999
0000
Unit0.01s
0000Discharge finish output OFF
Tare cancellation at the
time of discharge finish
SQF-49
0
Invalid
1 Effective
All brand accumulation
clear
SQF-98 Clear accumulation times and accumulation value for all
brands
Memory clear SQF-99 Set the SQ function content is returned to setting default
Has been set as default