60
8-11. Accumulation
The accumulation function accumulates the load data.
Memorize the accumulation times, updated accumulation data and accumulation value
8-11-1. Operating condition for accumulation function
Operating condition for accumulation function is selected by function F-50.
Setting range: 000-111
10
0
digit: Accumulation command operation [0] Only at stable condition, [1] Always
10
1
digit: Automatic accumulating operation [0] OFF, [1] Synchronized with end signal,
[2] Automatic accumulation in stable
10
2
digit: Automatic accumulating condition [0] Only in OK condition, [1] with no condition
Default is set to [000].
8-11-2. Execute accumulation
(1) Manual accumulation
When the value set with 10
0
digit for F-50 is
0: the accumulation is executed by pressing key under the condition that the stability sign of
status display is lights.
1: the accumulation is executed by pressing key regardless of lighting on or off the stability
sign.
(2) Automatic accumulation
When the value set with 10
1
digit for F-50 is:
0: automatic accumulation does not work.
1: accumulation works automatically synchronizing with finish signal.
2: accumulation works automatically under the condition that the stability sign of status display lights.
Also, when the value set with 10
2
digit for F-50 in the condition that [1] is set with 10
1
digit for F-50 is:
0: accumulation works automatically in the condition that the finish signal outputs under lighting on
sign of OK in the status display.
1: accumulation works automatically in the condition that the finish signal output regardless of lighting
on or off the OK sign.
If the results exceed the display range of the accumulation value or accumulation times,
accumulation is not executed. The status display [ACCUM.] mark blinks.
Accumulating is prohibited if the result exceeds ±100% of the weighing capacity.
8-11-3. Display range of the accumulated value and count
The display range of the accumulation value is from –9 999 999 999 to 9 999 999 999.
The display range of the accumulated count is from 0 to 999 999.
The upper limit of accumulated value disregards the displayed decimal point.
Example. When the position of decimal point is 0.0, the upper limit of accumulated value is
9 999 999 99.9.
When the accumulated value and the accumulated count exceeding the display range results, the
additive of the count is not executed. As the error code display at sub display, please execute to clear
the accumulated value and count.