61
8-11-4. The clear of accumulation value / the accumulation times
Clear the accumulation value and the accumulation times.
There are four methods for accumulating as follows.
Press the key in accumulation display mode.
Set a key to [Accumulation clear] by setting F-55.
Clear all brand accumulation by setting external control I/O.
Clear all brand accumulation using SQ function SQF-98.
For details of accumulation display mode, see "Clause 3-1".
For details of SQ function setting, see "Clause 10".
8-12. Brands
Brand comparison values can be set for individual brand numbers.
Weighing is controlled using the various brand settings to ensure the target (OK) weight is achieved.
The CSD-903 is capable of storing up to eight different brands.
For details of the settings available for brands, see "9. Measurement mode".
8-12-1. Target of brand changeover
The brand number can be changed using function, external control input, or communication.
The changeover method enabled when changing the brand number is selected using the function F-51
setting.
To change the brand number in EzCTS mode, set function F-51 to [0: Changeover by function].
Setting range: 0 to 3
0: Changeover by function
The brand number can be changed by changing the function F-52 setting.
To change the brand number using standard RS485, RS-232C, or RS-422/485, change the brand
number using the communication command [@007052].
For details of communication commands, see "16-3-12. Data format of command mode".
1: Changeover by external control input
Brand number changeover can only be enabled using external control input. If changeover by external
control input has been selected, see "8-14. Setting of external control input".
2: Changeover by communication
This enables brand number changeover using the communication command [@0069].
For details of communication commands, see "16-3-12. Data format of command mode".
Default is set to [Changeover by key operation].
8-12-2. Brand number
The brand number enabled by measurement control is selected using function F-52.
Brand numbers 0 to 7 can be selected.
Default is set to [Brand No. 0].
8-13. Setting of F key
Operation of F key can be selected by function F-55.
Setting range: 0 ~ 9
0: OFF No setting
1: Print Input the print signal
2: Hold Input the holding signal
3: Batch start Input the signal to start batch
4: Emergency stop Input the signal to emergency stop