EasyManua.ls Logo

Minelab EQUINOX 900 - Noise Cancel; Auto Noise Cancel; Manual Noise Cancel*

Minelab EQUINOX 900
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25
CONTENTS
Detectors can become noisy due to electrical
interference from power lines, electrical
equipment or other detectors operating
nearby� The detector interprets this
interference as inconsistent, erratic detections�
The Noise Cancel setting allows you to change the noise
cancel channel� This slightly shifts the detector transmit
frequency to be less responsive to the source of the noise�
Noise Cancel affects both the audible detection noise level
and pinpointing performance
Noise Cancel adjustment is local; only the current Search
Mode Search Profile is affected by changes to this setting�
The Noise Cancel setting has 19 channels with a range
from −9 to 9� It has a default setting of 0 [zero] for all
Search Modes�
Perform a Noise Cancel (page 25) each time the
Frequency is changed�
Auto is the recommended Noise Cancel method�
AUTO NOISE CANCEL
Auto Noise Cancel automatically scans and listens to every
frequency channel and then selects the one with the least
interference�
1. Hold the coil stationary and away from the ground�
2. Press the Settings button to navigate to the
Noise Cancel setting�
3. Press the Accept/Reject button to initiate the Auto
Noise Cancel process� Auto Noise Cancel can also be
initiated on the EQUINOX 700 by pressing the Minus (–)
or Plus (+) buttons
4. The Auto Noise Cancel progress is indicated on the
Discrimination Scale, and by a series of ascending
tones�
When this process is complete (after approximately
5 seconds), the automatically selected channel
appears on the Target ID Display, and there are three
confirmation tones�
Note: While Auto Noise Cancel selects the
‘quietest’ channel based on several criteria, the
selected channel may still have some audible noise�
To try and reduce noise further, consider adjusting
Sensitivity
MANUAL NOISE CANCEL*
Setting the Noise Cancel manually allows you to listen to
each channel to select the one with the least interference
This can be useful when detecting in close proximity
to other detectors or in locations with lots of electrical
interference�
1. Hold the coil stationary and away from the ground�
2. Press the Settings button to navigate to the
Noise Cancel setting�
3. Press the Minus (–) or Plus (+) buttons to adjust the
channel�
The channel is shown on the Target ID Display� Pause
and listen to the interference levels — keep the detector
still during this process
4. Continue until you have chosen the channel with the
least interference
Noise Cancel
* EQUINOX 900 only

Other manuals for Minelab EQUINOX 900

Related product manuals