8.2 Entering Service Mode with a Stuck Actuator
To enter into service mode with the brush
actuator stuck in the up position
•With the machine turned off, unplug the P2 connector on the controller
•Turn the machine on and press the service mode switch up to 30
seconds, and then release.
•Plug the P2 connector back in with the machine still turned on.
•Press the lower side of the service mode switch to lower the brush deck.
Page 39
With the machine turned off, unplug the P2 connector on the controller
Turn the machine on and press the service mode switch up to 30
seconds, and then release.
Plug the P2 connector back in with the machine still turned on.
Press the lower side of the service mode switch to lower the brush deck.