EasyManuals Logo

Mira CODA PRO User Manual

Mira CODA PRO
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
17
Lubricants
Silicone based lubricants must only be used on the rubber seals.
Caution! Oil based or other lubricant types may cause rapid deterioration of seals.
Cleaning
The chrome plated parts should be cleaned using a mild washing up detergent or
soap solution, rinsed and then wiped dry with a soft cloth.
Warning! Many household cleaners contain abrasive and chemical substances,
and should not be used for cleaning plated or plastic ttings.
Do not use descalents on this product.
Maintaining the Non-Return Valves
Sealing Washer / Filter
Inlet Connector / Non-Return
Valve Housing
Non-Return Valve
The non-return valves are located in the thermostatic bar valve body, and are
accessible through the inlet connectors.
Caution! Make sure that the non-return valves are installed correctly to prevent
crossow or malfunction of the valve.
1. With the water supplies turned off and
the thermostatic bar valve removed,
remove the sealing washer / lter.
2. Unscrew the non-return valve housing
using a 12 mm hexagonal wrench.
Note! The non-return valve housing
has a Left Hand Thread, turn
clockwise to unscrew.
3. Carefully remove the non-return
valve and clean out any debris.
4. On re assembly make sure that the
non-return valve is tted the correct
way round (with the arrow indicating
the ow pointing towards the valve).
Filters
The sealing washers/lters are located in the inlet connector. Clean or renew as
necessary.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mira CODA PRO and is the answer not in the manual?

Mira CODA PRO Specifications

General IconGeneral
Enclosure RatingIP65
Weight300g
Measurement Range0 - 100%
Operating Humidity0-95% RH (non-condensing)
Output4-20 mA

Related product manuals