Hardware Installation
Cables must not pull or create a lateral stress on the connectors; that is, they must be
long enough.
Cables must be installed in such a way the personnel working in the vicinity of the
equipment do not trip on them.
Keep cables away from:
Sources of electrical noise such as radios, transmitters, and broadband amplifiers
Power lines
Fluorescent lighting fixtures
Liquids or moisture
Heat sources
For more information, see Ethernet Twisted Pair Cabling Plant, Power and Grounding
Guidelines.
3.3.3 Tools and Equipment
Screwdriver as required for attaching brackets to rack
ESD wrist strap
Earth ground cable
Warning:
The earth ground cable should be the same size (18 AWG minimum) as the earth
cable of the provided power cord. Otherwise, make sure the earth ground cable
meets the standards and requirements of your local electrical code. The type of
the cable is likely to have VW-1 or RT1 markings on the cable.
RJ45 cables for LAN connections
RJ48 cables for PRI connections
RJ11 cables for FXS and FXO connections
3.4 Installation Checklist
Task Verified by Date
Network information available and recorded in site log.
Location requirements verified.
Site power Voltage
Installation site pre-power check completed.
23 EX Controller Installation and Administration Guide

Table of Contents

Other manuals for Mitel MiVoice Business EX Controller

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitel MiVoice Business EX Controller and is the answer not in the manual?

Mitel MiVoice Business EX Controller Specifications

General IconGeneral
BrandMitel
ModelMiVoice Business EX Controller
CategoryController
LanguageEnglish

Related product manuals