76
FX
3G
/FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
3 Instruction List
3.3 Applied Instructions ... in Ascending Order of FNC
External Device
170 GRY
Decimal to Gray Code
Conversion
333 ––3 – 3
Section
22.1
171 GBIN
Gray Code to Decimal
Conversion
333 ––3 – 3
Section
22.2
172 to
175
– –
176 RD3A
Read form Dedicated
Analog Block
333 – 3
*1
3 *1
Section
22.3
177 WR3A
Write to Dedicated Analog
Block
333 – 3
*1
3 *1
Section
22.4
178,
179
– –
Extension Function
180 EXTR
External ROM Function
(FX2N/FX2NC)
–––––
*1
–*1 –
Others
181 – –
182 COMRD
Read Device Comment Data
3 *5––––––
Section
24.1
183 – –
184 RND
Random Number Generation
33 ––––––
Section
24.2
185 – –
186 DUTY Timing Pulse Generation 3 *5––––––
Section
24.3
187 – –
188 CRC Cyclic Redundancy Check 33 ––––––
Section
24.4
189 HCMOV High-speed Counter Move 3 *4––––––
Section
24.5
Block Data Operation
190,
191
– –
192 BK+ Block Data Addition 3 *5––––––
Section
25.1
193 BK- Block Data Subtraction 3 *5––––––
Section
25.2
*1: The instruction is provided in the FX
2N
/FX
2NC
Series Ver. 3.00 or later. *6: The instruction is provided in the FX
3G
Series Ver. 1.10 or later.
*2: The function is changed in the FX
3UC
Series Ver. 1.30 or later. *7: The instruction is provided in the FX
3U
/FX
3UC
Series Ver. 2.61 or later.
*3: The instruction is provided in the FX
3UC
Series Ver. 1.30 or later. *8: The instruction is provided in the FX
3U
/FX
3UC
Series Ver. 2.70 or later.
*4: The function is changed in the FX
3UC
Series Ver. 2.20 or later. *9: The instruction is provided in the FX
3G
Series Ver. 1.40 or later.
*5: The instruction is provided in the FX
3UC
Series Ver. 2.20 or later.
FNC No. Mnemonic Symbol Function
FX3U
FX3UC
FX3G
Applicable PLC
Reference
FX1S
FX1N
FX2N
FX1NC
FX2NC
DSGRY
DSGBIN
DRD3A m2m1
SWR3A m2m1
SD3
EXTR
SD2SD1S
COMRD DS
RND D
DUTY Dn2n1
nCRC DS
nHCMOV DS
nDS2S1BK+
nDS2S1BK-