Appendix A-1-2 Cautions on writing during RUN
"In the FX3G, FX3U and FX3UC PLCs, writing is enabled during RUN (program changes during RUN mode) using the
following programming tools."
→ For the operating procedure of and cautions on writing during RUN,
refer to the respective programming tool manual.
Programming tools which support writing during RUN
• Japanese version
*1. Write during RUN is not possible with a SFC program.
*2. Write during RUN is not possible with a list program or a SFC program.
Programming tool PLC Version Remarks
GX Works2
*1
(SWDNC-GXW2-J)
FX3G Ver. 1.07H or later
Writing in the instruction and device ranges during RUN is supported in FX3G
PLCs Ver. 1.10.
FX3U/FX3UC
Ver. 1.07H or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs earlier than Ver. 2.70.
Ver. 1.45X or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs Ver. 2.70.
GX Developer
*2
(SWD5C-GPPW-J)
FX3G
Ver. 2.00A or later
Writing in the instruction and device ranges during RUN is supported in FX2N
PLCs Ver. 1.00.
Ver. 5.00A or later
Writing in the instruction and device ranges during RUN is supported in FX1N
PLCs Ver. 1.00.
Ver. 8.72A or later
Writing in the instruction and device ranges during RUN is supported in FX3G
PLCs earlier than Ver. 1.10.
Ver. 8.76E or later
Writing in the instruction and device ranges during RUN is supported in FX3G
PLCs Ver. 1.10.
FX3U/FX3UC
Ver. 7.00A or later
Writing in the instruction and device ranges during RUN is supported in FX2N
PLCs Ver. 3.00.
Ver. 8.13P or later
Writing in the instruction and device ranges during RUN is supported in FX3UC
PLCs earlier than Ver. 1.30.
Ver. 8.18U or later
Writing in the instruction and device ranges during RUN is supported in FX3UC
PLCs earlier than Ver. 2.20.
Ver. 8.23Z or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs earlier than Ver. 2.30.
Ver. 8.29F or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs earlier than Ver. 2.61.
Ver. 8.82L or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs Ver. 2.61.
FX-PCS/WIN
*2
FX3G Ver. 4.00 or later
Writing in the instruction and device ranges during RUN is supported in FX1N
PLCs Ver. 1.00.
FX3U/FX3UC
Ver. 1.00 or later
Writing in the instruction and device ranges during RUN is supported in FX2
PLCs Ver. 3.30.
Ver. 2.00 or later
Writing in the instruction and device ranges during RUN is supported in FX
2N
PLCs Ver. 1.00.
Ver. 4.20 or later
Writing in the instruction and device ranges during RUN is supported in FX
2N
PLCs Ver. 3.00.